Ill. Admin. Code tit. 62, § 220.130
a) Explosives and blasting.
b) Magazines; location.
In addition to the magazine location provisions contained in existing federal and state statutes and rules, the magazine shall be located outside the blasting area.
c) Magazine; storage.
In addition to storage requirements contained in existing federal and state statutes and rules, the following shall apply:
d) Persons authorized to use explosives.
e) Transport of explosives.
f) Priming and stemming of explosives.
g) Firing of explosive charges.
7) Except when being tested with a blasting galvanometer:
h) Detonating cord.
6) When firing from one (1) to fifteen (15) blastholes with safety fuse ignited individually using hand-held lighters, the fuses shall be of such lengths to provide the minimum burning time specified in the following table for a particular size round:
A)
| Number of holes in a round | Minimum burning time, minutes | |
| 1 | 2 | |
| 2-5 | 2⅔ | |
| 6-10 | 3⅓ | |
| 11-15 | 5 |
i) Blasting area.
6) Boreholes shall be stemmed immediately after loading. Whenever possible, shots shall be fired immediately after the borehole is stemmed. If shots are not fired immediately thereafter, the boreholes shall be guarded or otherwise protected as is provided in Section 220.130(i)(7) of this Part.
j) Misfires and damaged explosives.
k) Blasting agents; special provisions.