Ill. Admin. Code tit. 41, § 100.7
b) Incorporated Standards
National Fire Protection Association
Batterymarch Park
Quincy MA 02269
NFPA 101, Life Safety Code (2015) (adopted in its entirety, subject to the OSFM modifications in subsection (c)).
NFPA 101, Life Safety Code (2000) (only to the extent cited in subsections (c)(1), (c)(2) and (c)(6)).
NFPA 101A, Guide on Alternative Approaches to Life Safety (2016).
NFPA 101A, Guide on Alternative Approaches to Life Safety (2001) (only to the extent cited in subsection (c)(1)).
NFPA 914, Code for Fire Protection of Historic Structures (2010) (only to the extent cited in Section 100.8).
NFPA 80, Standard for Fire Doors and Other Opening Protectives (2013) (only to the extent cited in subsection (c)(10)(I)).
NFPA 1, Fire Code (2015) (only to the extent cited in subsection (c)(11)).
c) Modifications to the Life Safety Code
1) High Rise Buildings
All existing high rise buildings, as defined in NFPA 101, Life Safety Code (all applicable Sections), shall comply with the sprinkler requirements prescribed in the 2000 edition of NFPA 101, Life Safety Code, effective January 1, 2002. Use of a Fire Safety Evaluation System (FSES) for compliance with this Section must adhere to NFPA 101A, Guide on Alternative Approaches to Life Safety (2001).
2) Assembly Occupancies
3) Day Care Occupancies
A) Child Care Facilities (see the Child Care Act of 1969 [225 ILCS 101])
iii) In day care homes in which clients occupy a level below the level of exit discharge, means of escape shall be provided in accordance with either the applicable requirements of NFPA 101, Life Safety Code (2015) or with one of the following:
• If a means of escape discharging directly to the outside at the basement level is not provided, requiring occupants to traverse another level of the home to exit, the path of escape through the level of exit discharge shall be separated from the remainder of that level of the home by construction providing a minimum fire resistance rating of 1-hour; or
• The home shall be equipped with smoke alarms permanently powered by the building's electrical system and wired so that the actuation of one smoke alarm will actuate all the smoke alarms in the dwelling. At least one such smoke alarm shall be located on each level of the occupancy (excluding unoccupied attics and crawl spaces), and the path of escape through the level of exit discharge (from the basement door to the exterior door of the home) must be protected by automatic fire sprinklers. Listed residential sprinklers shall be used and the installation shall be made in accordance with 41 Ill. Adm. Code 109 and codes and standards referenced in that Part.
B) Windows for Rescue in Existing Day Care Centers
Windows for rescue required by NFPA 101, Life Safety Code (2015), Section 17.2.11.1, are not required for existing day care centers.
C) Day Care Homes − New and Existing
Day care homes shall be defined as new and existing based on the date the original home construction was completed and available for residency.
D) Smoke Detection in Corridors Outside Day Care Homes Located Within a Building of Another Occupancy
A smoke alarm system installed as prescribed in this subsection (c)(3)(D) shall be permitted to be used in day care homes located within a building of another occupancy in lieu of a smoke detection system connected to a fire alarm system as required by NFPA 101, Life Safety Code (2015), Sections 16.6.3.4.2 and 17.6.3.4.2:
4) One- and Two-Family Dwellings
NFPA 101, Life Safety Code (2015), Chapter 24 (One- and Two-Family Dwellings) is adopted as recommended guidelines only, except when referenced as being required for compliance with this Part.
5) Communicating Spaces
Corridors shall not be required to be separated from communicating spaces as required in NFPA 101, Life Safety Code (2015), Section 8.6.6, in new or existing occupancies, provided all of the following criteria are met:
6) Mixed Occupancies
All existing mixed occupancies, as defined by NFPA 101, Life Safety Code, shall, at minimum, continue to comply with the requirements of Section 6.1.14 of NFPA 101, Life Safety Code (2000), effective January 1, 2002, but shall also be permitted to comply with the requirements of Section 6.1.14 of NFPA 101, Life Safety Code (2015).
7) Determination of "Story" in Occupancies
The criteria for what a "story level" is, as found in NFPA 101, Life Safety Code (2015), Section 16.1.1.8 and 17.1.1.8 are permitted to be used for all occupancies found in NFPA 101, Life Safety Code (2015).
8) Use of NFPA 101A for Apartment Building Occupancies
NFPA 101A, Guide on Alternative Approaches to Life Safety (2016), Sections 7.6 and 7.7, may be used to demonstrate equivalent protection in apartment buildings, regardless of whether they contain board and care occupancies or house board and care clients receiving personal care services.
9) Means of Egress Design to Travel to Direct Exits and Travel to Windows for Rescue in Educational Occupancies and Day Care Centers
Travel to exits or to windows for rescue shall be permitted as follows in educational occupancies and day care centers:
10) Door Locking to Prevent Unwanted Entry
Occupancies shall be permitted to provide locking to prevent unwanted entry as long as all of the following requirements are met:
11) Use of Combustible Vegetation in Buildings
Combustible vegetation within buildings shall comply with NFPA 1, Fire Code (2015), Section 10.13.
12) Windows for Rescue and Windows Used as a Secondary Means of Escape
Where windows for rescue are required or where they are used as a secondary means of escape, the bottom sill of the window shall be not more than 44 inches above the floor as required by NFPA 101, Life Safety Code (2015), or a permanently fixed stair or ramp shall be installed at the window to allow occupants to be within 44 inches of the bottom window sill when standing atop the stair or ramp. The stair or ramp shall be at least the width of the window or a minimum of 36 inches in width, whichever is larger.
13) Size and Access to Secondary Means of Escape
If a window is used as a secondary means of escape as permitted by NFPA 101, Life Safety Code (2015) and the size is not in accordance with NFPA 101, Life Safety Code (2015), the owner or operator of the facility using this window as a secondary means of escape must demonstrate to an on-site representative of OSFM that all occupants (staff and clients) can escape through the window to the exterior of the facility in 3 minutes or less.
d) The materials incorporated by this Section are on file with OSFM at the following locations:
1035 Stevenson Drive
Springfield IL 62703-4259
James R. Thompson Center
100 W. Randolph Street, Ste. 4-600
Chicago IL 60601
All existing assembly occupancies, as defined in NFPA 101 (Chapter 13), shall comply with the sprinkler requirements prescribed in the 2000 edition of NFPA 101, Life Safety Code, effective January 1, 2002.
(Source: Amended at 43 Ill. Reg. 10008, effective January 1, 2020)