a) Inservice Inspection Records:
- 1) ASME data reports if applicable
- 2) Date object was placed in service
- 3) Record of inservice inspections including inspector's signature
b) Repair Record:
- 1) Calculations
- 2) Material test reports
- 3) Traveler
- 4) Welding procedure specifications
- 5) Welding procedure qualification records
- 6) Welder qualification records
- 7) Heat treat procedure
- 8) Time-temperature charts
- 9) NDE procedures
- 10) NDE examination reports including NDE technician signature
The Owner-User Quality Control System shall describe the procedures to be followed to ensure the following records are maintained for the life of the pressure vessel or boiler.
(Source: Amended at 17 Ill. Reg. 14917, effective September 1, 1993)