Ill. Admin. Code tit. 35, § 220.250
a) Operate the collection system such that gas is collected from each area, cell, or group of cells in the MSW landfill in which the initial solid waste has been in place for:
b) Operate the collection system with negative pressure at each wellhead except under the following conditions:
c) Operate each interior wellhead in the collection system with a landfill gas temperature less than 55°C (131°F) and with either a nitrogen level less than 20 percent or an oxygen level less than 5 percent. The owner or operator may establish a higher operating temperature, nitrogen, or oxygen value at a particular well. A higher operating value demonstration that provides supporting data to show that the elevated parameter does not cause fires or significantly inhibit anaerobic decomposition by killing methagens must be approved by the Agency before such higher operating value may be used. Operating values shall be determined as follows:
2) The oxygen level shall be determined by an oxygen meter using Method 3A, Appendix A, 40 CFR 60, incorporated by reference in Section 220.130 of this Part, except that:
h) The collection and control system may be capped or removed provided:
Each owner or operator of an MSW landfill with a gas collection and control system shall: