- a) Each open-ended valve shall be equipped with a cap, blind flange, plug, or a second valve, except during operations requiring fluid flow through the open-ended valve.
- b) Each open-ended valve equipped with a second valve shall be operated in a manner such that the valve on the process fluid end is closed before the second valve is closed.
c) Components which are open-ended valves and which serve as a sampling connection shall be controlled such that:
- 1) A closed purge system or closed vent system shall return purged process fluid to the process line with no detectable volatile organic material emissions to the atmosphere, or
- 2) A closed purge system or closed vent system shall collect and recycle purged process fluid to the process line with no detectable volatile organic material emissions to the atmosphere, or
- 3) Purged process fluid shall be transported to a control device that complies with the requirements of Section 215.438.
- d) In-situ sampling systems are exempt from subsection (c).
(Source: Amended at 13 Ill. Reg. 10893, effective June 27, 1989)