Ill. Admin. Code tit. 35, § 570.APPENDIX B
1. Feedlot Runoff Volume = Total of Column (C) (cubic feet).
| 2. | Milking Parlor Washwater | = | gallons | x | .936 (cubic feet-per week). |
| day |
3. Design Runoff Volume (VR) = 1 + 2 (cubic feet).
5. To convert Runoff Volume (VR) from units of cubic feet into equivalent units of gallons, multiply cubic feet by 7.481 gallons/cubic feet.
* Multiplication factor corresponds to Q of the U.S.D.A. – S.C.S. runoff equation.
Storm event (I) is 1-year, 2-hour storm of 1.69 inches.
Curve numbers (CN) are 100-roof; 95-paved; 91-earthen.
S = (1000/CN) - 10
| Q | = | (I - 0.2S)2 |
| (I - 0.8S) |
Use VR (cubic feet) for designing field application area.
Procedure to Estimate Volume of Feedlot Runoff*
| (A) X | (B) = | (C) | |||
| Type of Drainage Area | Area (Square feet) | Multiplication Factor (feet) | Runoff Volume (Cubic feet) | ||
| Roof | 0.1408 | ||||
| Feedlot | |||||
| a. | Paved or Concrete | 0.0991 | |||
| b. | Earthen | 0.0748 |