Ill. Admin. Code tit. 35, § 204.420
a) "Good engineering practice", with respect to stack height, means the greater of:
2) The following:
A) For a stack in existence on January 12, 1979, and for which the owner or operator had obtained all necessary preconstruction approvals or permits required under 40 CFR 51 and 52 (incorporated by reference in Section 204.100):
Hg = 2.5H,
provided the owner or operator produces evidence that this equation was actually relied on in establishing an emission limitation;
B) For all other stacks:
Hg = H + 1.5L
where:
Hg = good engineering practice stack height, measured from the ground-level elevation at the base of the stack;
H = height of nearby structure or structures measured from the ground-level elevation at the base of the stack;
L = lesser dimension, height, or projected width of nearby structure or structures provided, that USEPA or the Agency may require the use of a field study or fluid model to verify good engineering practice stack height for the source; or
(Source: Amended at 49 Ill. Reg. 6332, effective April 23, 2025)