a) Apparatus
- 1) Ringstand approximately 10 cm in diameter
- 2) 100 ml graduated cylinder
- 3) 400 micron conical paint filter approximately 15 cm in diameter
- 4) Watch glass.
b) Procedure
- 1) Collect a 100 ml representative sample of the hazardous waste.
- 2) Mix the sample thoroughly.
- 3) Bring the sample and the filter to a temperature of not less than 20 degrees C (68 degrees F) and to ambient pressure.
- 4) Place the filter in the ringstand.
- 5) Place the sample in the filter and cover with the watch glass.
- 6) Maintain the sample and the filter at the temperature and pressure specified in paragraph (3) for five minutes.
- 7) Observe whether any fluid portion of the sample drops from the bottom of the filter during the period of time specified in paragraph (6).
(Source: Amended at 10 Ill. Reg. 4864, effective March 7, 1986)