Ill. Admin. Code tit. 35, § 229.APPENDIX C
e) The pollutant concentrations shall be adjusted to 7 percent oxygen using the following equation:
Cadj = Cmeas (20.9-7)/(20.9-%O2)
| Where: |
| Cadj | = | pollutant concentration adjusted to 7 percent oxygen; |
| Cmeas | = | pollutant concentration measured on a dry basis |
| (20.9-7) | = | 20.9 percent oxygen - 7 percent oxygen (defined oxygen corrective basis); |
| 20.9 | = | oxygen concentration in air, percent; and |
| %O2 | = | oxygen concentration measured on a dry basis, percent. |
l) Method 23, at 40 CFR 60, shall be used to measure total dioxin/furan emissions. As an alternative, the facility may elect to sample total dioxins/furans by installing, calibrating, maintaining, and operating a continuous automated sampling system for monitoring dioxin/furan emissions. The minimum sample time for Method 23 sampling shall be 4 hours per test run. If the affected facility has selected the TEQ for dioxin/furans (set out in Appendix A of this Part), as provided under Section 229.125 or 229.126 of this Part, whichever is applicable, the following procedures shall be used to determine compliance:
m) Method 26 or 26A, at 40 CFR 60, shall be used to measure HCl emissions. As an alternative, an HCl CEMS may be used to measure HCl emissions. Before January 1, 2014, if the affected facility has selected the percentage reduction standard for HCl as provided under Section 229.125(a) or 229.126(a) of this Part, whichever is applicable, the percentage reduction in HCl emissions (%RHCl) is computed using the following formula:
(%RHCl) = ((Ei-Eo)/Ei) x 100
Where:
| %RHCl | = | percentage reduction of HCI emissions achieved; |
| Ei | = | HCI emissions concentration measured at the control device inlet, corrected to 7 percent oxygen (dry basis); and |
| Eo | = | metal emissions concentration (Pb, Cd, or Hg) measured at the control device outlet, corrected to 7 percent oxygen (dry basis). |
n) Method 29, at 40 CFR 60, shall be used to measure Pb, Cd, and Hg emissions. As an alternative, ASTM D6784-02 may be used to measure Hg emissions; a multi-metals CEMS or Hg CEMS may be used to measure Pb, Cd, and Hg emissions; or the facility may elect to sample Hg by installing, calibrating, maintaining, and operating a continuous automated sampling system for monitoring Hg emissions. Before January 1, 2014, if the affected facility has selected the percentage reduction standards for metals as provided in Section 229.125(a) or 229.126(a) of this Part, whichever is applicable, the percentage reduction in emissions (%Rmetal) is computed using the following formula:
(%Rmetal) = ((Ei-Eo)/Ei) x 100
Where:
| %RMETAL | = | percentage reduction of metal emissions (Pb, Cd, or Hg) achieved; |
| Ei | = | metal emissions concentration (Pb, Cd, or Hg) measured at the control device inlet, corrected to 7 percent oxygen (dry basis); and |
| EO | = | metal emissions concentration (Pb, Cd, or Hg) measured at the control device outlet, corrected to 7 percent oxygen (dry basis). |
The following test methods and procedures shall be used as specified in Section 229.140(e) of this Part, when conducting any performance test for the purpose of demonstrating compliance with the emissions limits established under this Part.
(Source: Amended at 35 Ill. Reg. 16615, effective September 30, 2011)