Ill. Admin. Code tit. 32, § 622.40
b) Persons producing or in possession of water treatment residuals identified in subsection (a) shall:
2) Limit Dose to Workers and Members of the Public. Registrants shall conduct operations so that:
D) Procedures are in place to ensure doses to workers are kept as low as reasonably achievable and in compliance with this Part. Emergency work that results in work duties or exposures outside the scope of TENORM awareness training provided for workers as outlined in Section 622.50(a) shall be reported to the Agency within 45 days. The report shall include proposed revisions to the registrant’s training agenda or operating procedures necessary to maintain compliance with this Part.
AGENCY NOTE: Calculation of doses for compliance with this subsection may be based upon calibrated radiation meter survey data and worker occupancy times, or work area monitoring, rather than an individual worker dosimetry program.
3) Employ institutional and engineered controls to limit exposure of water treatment residuals to personnel and the environment.
5) Perform radiation surveys to demonstrate compliance with this Section. Surveys shall be done to evaluate:
6) Ensure use of calibrated radiation detection instruments. Instruments and equipment used for quantitative radiation measurements (e.g., exposure rate and contamination monitoring) shall be calibrated at intervals not to exceed 12 months for the radiation measured. To satisfy this requirement, the registrant shall:
7) Provide notices and instructions to workers.
ii) Agency Form KLA.001 “Notice to Employees”;
c) Any person who receives, possesses, uses, or transfers water treatment residuals with concentrations of combined radium greater than 200 pCi/g (dry weight basis), and is not otherwise a registrant under Section 622.30 (including, but not limited to, vendors, contractors, service providers, consultants, low-level radioactive waste brokers, or persons performing decommissioning work) shall obtain a radioactive material license 32 Ill. Adm. Code 330.
AGENCY NOTE: The requirement to obtain a license does not apply to the transportation of water treatment residuals. However, persons transporting water treatment residuals must comply with all other applicable federal, State and local government regulations.
d) The registrant shall notify the Agency before removing material identified in subsection (a) from the facility for disposal, treatment, or transport. Such notification shall include the location, quantity, proposed dates, and proposed method for disposal.
2) Before releasing, repurposing, or repair of equipment (piping, pumps, tanks, etc.) that has been contaminated with material identified in subsection (a), the registrant shall remove or provide for the removal of such contaminants and ensure that:
B) The total amount of contamination does not exceed the quantities listed in Appendix C to 10 CFR 20.
AGENCY NOTE: Notification to the Agency is not required when transport is incidental to shipment for analytical services.
AGENCY NOTE: For the purposes of this subsection, "disposal, treatment, or transport" does not apply to discharge to a sanitary sewer.
e) Registrants may dispose of material by:
1) Disposal by Release into Sanitary Sewerage. A registrant may discharge material into the sanitary sewer if each of the following conditions is satisfied:
B) Wastewater treatment facilities receiving discharges authorized this subsection are registered and in compliance with the provisions of Section 622.30; and
AGENCY NOTE: Discharges of material identified in subsection (a) to a wastewater treatment facility will require that facility to register under Section 622.30 due to the unquantified impact the material will have on the facility's water treatment residuals. Receiving wastewater treatment plants may have local pretreatment standards restricting such discharges.
3) The material may be disposed of at a facility authorized to dispose of such material in accordance with any federal or State solid or hazardous waste laws as long as the following conditions are satisfied: