(1) Electrical systems and components include the following:
- (a) Service entrance conductors, drip loop, cables, and raceways;
- (b) Main service equipment and main disconnects;
- (c) Service grounding;
- (d) Interior components of main service panels and sub panels;
- (e) Conductors;
- (f) Over current protection devices;
- (g) Readily accessible installed lighting fixtures, switches, and receptacles;
- (h) Ground fault circuit interrupters;
- (i) Amperage and voltage rating of electrical service;
- (j) Main disconnect(s);
- (k) Methods or types of wiring;
- (l) Smoke detectors;
- (m) Carbon monoxide detectors;
- (n) Arc fault circuit interrupters.
- (2) The inspector shall inspect all of the visible and readily accessible electrical systems and components.
(3) The inspector is not required to inspect:
- (a) Remote control devices;
- (b) Security alarm systems and components;
- (c) Low voltage wiring, systems and components, ancillary wiring and systems and components not a part of the primary electrical power distribution system;
- (d) Generators, photovoltaic solar collectors or battery or electrical storage devices and associated equipment.
(4) The inspector is not required to:
- (a) Measure amperage, voltage or impedance;
- (b) Perform a load calculation;
- (c) Insert any tool, probe, or device into any electrical component;
- (d) Determine the accuracy of circuit labeling.
Rulemaking Authority 468.8325 FS. Law Implemented 468.8323, 468.832(1)(j) FS. History‒New 10-22-13.