D.C. Mun. Regs. tit. 12-A, § 713
Strike Section 713.14.1 of the International Building Code in its entirety and insert new Section 713.14.1 to the Building Code in its place to read as follows:
713.14.1 Elevator lobby. An enclosed elevator lobby shall be provided at each floor where an elevator shaft enclosure connects more than three stories. The lobby enclosure shall separate the elevator shaft enclosure doors from each floor by fire partitions. In addition to the requirements in Section 708 for fire partitions, doors protecting openings in the elevator lobby enclosure walls shall also comply with Section 716.5.3 as required for corridor walls, and penetrations of the elevator lobby enclosure by ducts and air transfer openings shall be protected as required for corridors in accordance with Section 717.5.4.1. Elevator lobbies shall have at least one means of egress complying with Chapter 10 and other provisions within this code.
1. Enclosed elevator lobbies are not required at the street floor, provided the entire street floor is equipped with an automatic sprinkler system in accordance
with
Section
903.3.1
.1.
2. Elevators not required to be located in a shaft in accordance with Section 712.1 are not required to have enclosed elevator lobbies.
3. Enclosed elevator lobbies are not required where additional doors are provided at the
hoistway opening in accordance with Section 3002.6. Such doors shall comply with the smoke and draft control door assembly requirements in Section 716.5.3.1 when tested in accordance with UL 1784 without an artificial bottom seal.
ed
elevato
r
lobbies
are not
require
d
where
the
buildin
g is
protect
ed by
an
automa
tic
sprinkl
er
system
installe
d in
accord
ance
with
Section
903.3.1
.1 or
903.3.1
.2.
This
excepti
on
shall
not
apply
to the
followi
ng:
4.1. Group I-2 occupancies; and
4.2. Group I-3 occupancies.-
5. Smoke
partitions
shall
be
permitted
in
lieu of
fire
partitions to
separate
the
elevator
lobby
at each
floor
where
the
building
is
equipped
throughout
with an
automatic
sprinkler
system
installed
in
accordance
with
Section
903.3.1
.1 or
903.3.1
.2. In
addition
to the
requirements
in
Section
710 for
smoke
partitio
ns,
doors
protect
ing
openin
gs in
the
smoke
partitio
ns
shall
also
comply
with
Section
s
710.5.2
.2,
710.5.2
.3, and
716.5.9
and
duct
penetra
tions
of the
smoke
partitio
ns
shall
be
protect
ed as
require
d for
corrido
rs in
accord
ance
with
Section
717.5.4
.1.
6. Enclos
ed
elevato
r
lobbies
are not
require
d
where
the
elevato
r
hoistw
ay is
pressur
ized in
accord
ance
with
Section
909.21.
7. Enclos
ed
elevato
r
lobbies
are not
require
d
where
the
elevato
r
serves
only
open
parkin
g
garage
s in
accord
ance
with
Section
406.5.
SOURCE: Final Rulemaking published at 61 DCR 2782 (March 28, 2014 – Part 2).
The District of Columbia Building Code (2013), referred to as the “Building Code,” consists of the 2012 edition of the International Building Code as amended by the District of Columbia Building Code Supplement (2013)(12 DCMR A). The International Building Code is copyrighted by the International Code Council and therefore is not republished here. However, a copy of the text may be obtained at: