1101.1 The development standards of this section and Subtitle K § 1102 apply to all BF zones except as modified for a specific zone, in which case the modified zone-specific standard shall apply. When only a portion of a development standard is modified the remaining portions of the development standards shall still apply.
1101.2 A court is not required in a BF zone, but where provided, it shall have the following minimum dimensions:
TABLE K § 1101.2: MINIMUM COURT DIMENSIONS
| Type of Structure | Open Court Minimum Width | Closed Court Minimum Width | Closed Court Minimum Area |
|---|---|---|---|
| Detached, Semi-detached, Row Dwellings, and Flats | N/A | N/A | N/A |
| Residential, more than 3 units | 2.5 inches per foot of height of court; 10 ft. minimum | 2.5 inches per foot of height of court; 12 ft. minimum | Twice the square of the required closed court width; 250 square ft. minimum |
| Non-residential and Lodging | 2.5 inches per foot of height of court; 6 ft. minimum | 2.5 inches per foot of height of court; 10 ft. minimum | Twice the square of the required closed court width; 250 square ft. minimum |