49 C.F.R. § 572.77
(2) The head and thorax assembly may be instrumented either with a Type A or Type B accelerometer.
(b) Head accelerometers.
(2) The head has three orthogonally mounted accelerometers aligned as follows:
(c) Thoracic accelerometers.
(2) The sternum-thoracic assembly has three orthogonally mounted accelerometers aligned as follows:
(f) Recording outputs. Record the outputs of acceleration and force-sensing devices installed in the dummy and in the test apparatus specified in this part, in individual channels that conform to the requirements of SAE Recommended Practice J211, October 1988, with channel classes as set out in the following table C.
| Device | Channel |
|---|---|
| Head acceleration | Class 1000 |
| Pendulum acceleration | Class 60 |
| Thorax acceleration | Class 180 |
| Femur-force | Class 600 |
The mountings for sensing devices shall have no resonance frequency within a range of 3 times the frequency range of the applicable channel class.