49 C.F.R. § 393.104
(e) Manufacturing standards for tiedown assemblies. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening devices used to secure articles of cargo to, or in, commercial motor vehicles must conform to the following applicable standards:
| An assembly component of . . . | Must conform to . . . |
|---|---|
| (1) Steel strapping 1 2 | Standard Specification for Strapping, Flat Steel and Seals, American Society for Testing and Materials (ASTM) D3953-97, February 1998. 4 |
| (2) Chain | National Association of Chain Manufacturers' Welded Steel Chain Specifications, dated September 28, 2005. 4 |
| (3) Webbing | Web Sling and Tiedown Association's Recommended Standard Specification for Synthetic Web Tiedowns, WSTDA-T1, 1998. 4 |
| (4) Wire rope 3 | Wire Rope Technical Board's Wire Rope Users Manual, 2nd Edition, November 1985. 4 |
| (5) Cordage | Cordage Institute rope standard: |
| (i) PETRS-2, Polyester Fiber Rope, three-Strand and eight-Strand Constructions, January 1993; 4 | |
| (ii) PPRS-2, Polypropylene Fiber Rope, three-Strand and eight-Strand Constructions, August 1992; 4 | |
| (iii) CRS-1, Polyester/Polypropylene Composite Rope Specifications, three-Strand and eight-Strand Standard Construction, May 1979; 4 | |
| (iv) NRS-1, Nylon Rope Specifications, three-Strand and eight-Strand Standard Construction, May 1979; 4 and | |
| (v) C-1, Double Braided Nylon Rope Specifications DBN, January 1984. 4 | |
| 1 Steel strapping not marked by the manufacturer with a working load limit will be considered to have a working load limit equal to one-fourth of the breaking strength listed in ASTM D3953-97. | |
| 2 Steel strapping 25.4 mm (1 inch) or wider must have at least two pairs of crimps in each seal and, when an end-over-end lap joint is formed, must be sealed with at least two seals. | |
| 3 Wire rope which is not marked by the manufacturer with a working load limit shall be considered to have a working load limit equal to one-fourth of the nominal strength listed in the manual. | |
| 4 See § 393.7 for information on the incorporation by reference and availability of this document. |
(f) Use of tiedowns.
[67 FR 61225, Sept. 27, 2002, as amended at 71 FR 35833, June 22, 2006]