(a) Each operator shall maintain current maps and records of its pipeline systems that include at least the following information:
(1) Location and identification of the following pipeline facilities:
- (i) Breakout tanks;
- (ii) Pump stations;
- (iii) Scraper and sphere facilities;
- (iv) Pipeline valves;
- (v) Facilities to which § 195.402(c)(9) applies;
- (vi) Rights-of-way; and
- (vii) Safety devices to which § 195.428 applies.
- (2) All crossings of public roads, railroads, rivers, buried utilities, and foreign pipelines.
- (3) The maximum operating pressure of each pipeline.
- (4) The diameter, grade, type, and nominal wall thickness of all pipe.
(b) Each operator shall maintain for at least 3 years daily operating records that indicate—
- (1) The discharge pressure at each pump station; and
- (2) Any emergency or abnormal operation to which the procedures under § 195.402 apply.
(c) Each operator shall maintain the following records for the periods specified:
- (1) The date, location, and description of each repair made to pipe shall be maintained for the useful life of the pipe.
- (2) The date, location, and description of each repair made to parts of the pipeline system other than pipe shall be maintained for at least 1 year.
- (3) A record of each inspection and test required by this subpart shall be maintained for at least 2 years or until the next inspection or test is performed, whichever is longer.
[Amdt. 195-22, 46 FR 38360, July 27, 1981, as amended by Amdt. 195-34, 50 FR 34474, Aug. 26, 1985; Amdt. 195-173, 66 FR 67004, Dec. 27, 2001]