49 C.F.R. § 192.105
(a) The design pressure for steel pipe is determined in accordance with the following formula:
P = (2 St/D) × F × E × T
P = Design pressure in pounds per square inch (kPa) gauge. S = Yield strength in pounds per square inch (kPa) determined in accordance with § 192.107. D = Nominal outside diameter of the pipe in inches (millimeters). t = Nominal wall thickness of the pipe in inches (millimeters). If this is unknown, it is determined in accordance with § 192.109. Additional wall thickness required for concurrent external loads in accordance with § 192.103 may not be included in computing design pressure. F = Design factor determined in accordance with § 192.111. E = Longitudinal joint factor determined in accordance with § 192.113. T = Temperature derating factor determined in accordance with § 192.115.
[35 FR 13257, Aug. 19, 1970, as amended by Amdt. 192-47, 49 FR 7569, Mar. 1, 1984; Amdt. 192-85, 63 FR 37502, July 13, 1998]