49 C.F.R. § 179.220-25
(a) To certify that the tank complies with all specification requirements, each outer shell must be plainly and permanently stamped in letters and figures at least 3/8-inch high into the metal near the center of both outside heads as follows:
| Examples of required stamping | |
|---|---|
| Specifications | DOT-115A60W6. |
| Inner container: | |
| Material | ASTM A240-316L. |
| Shell thickness | Shell 0.167 in. |
| Head thickness | Head 0.150 in. |
| Tank builders initials | ABC. |
| Date of original test | 00-0000. |
| Outer shell: | |
| Material | ASTM A285-C. |
| Tank builders initials | WYZ. |
| Car assembler (if other than inner container or outer shell builders) | DEF. |
[Amdt. 179-9, 36 FR 21343, Nov. 6, 1971, as amended at 77 FR 37986, June 25, 2012]