The following doors must always be Class 3:
- (a) Doors in all locations not addressed in §§ 170.255 and 170.260.
- (b) Doors between coal bunkers below the bulkhead deck that must be opened at sea.
- (c) Doors into trunkways that pass through more than one main transverse watertight bulkhead if the door sills are less than 2.14 meters above the deepest load line.
(d) Doors below a deck, the molded line of which, at its lowest point at side, is less than 2.14 meters (7 feet) above the deepest load line if—
- (1) The vessel is engaged on a short international voyage as defined in § 171.010 of this subchapter; and
- (2) The vessel is required by § 171.065 of this subchapter to have a factor of subdivision of 0.5 or less.
[CGD 79-023, 48 FR 51010, Nov. 4, 1983, as amended by CGD 85-080, 61 FR 944, Jan. 10, 1996; CGD 96-041, 61 FR 50734, Sept. 27, 1996]