(b) Inflation mechanisms.
(1) Each inflatable lifejacket must have
- (i) At least one automatic inflation mechanism;
- (ii) At least two manual inflation mechanisms on separate chambers;
- (iii) At least one oral inflation mechanism on each chamber; and
- (iv) At least one manual inflation mechanism or one automatic inflation mechanism on each inflation chamber.
(2) Each inflation mechanism must
- (i) Have an intended method of operation that is obvious to an untrained wearer;
- (ii) Not require tools to activate the mechanism;
- (iii) Be located outside its inflation chamber; and
- (iv) Be in a ready to use condition.
(3) Each oral inflation mechanism must
- (i) Be easily accessible after inflation for the wearer to “top off” each chamber by mouth;
- (ii) Operate without pulling on the mechanism;
- (iii) Not be able to be locked in the open or closed position; and
- (iv) Have a non-toxic mouthpiece.
(4) Each manual inflation mechanism must
- (i) Provide an easy means of inflation that requires only one deliberate action on the part of the wearer to actuate it;
- (ii) Have a simple method for replacing its inflation medium cartridge; and
- (iii) Be operated by pulling on an inflation handle that is marked “Jerk to Inflate” at two visible locations.
(5) Each automatic inflation mechanism must
- (i) Have a simple method for replacing its inflation medium cartridge and water sensitive element;
- (ii) Have an obvious method of indicating whether the mechanism has been activated; and
- (iii) Be incapable of assembly without its water sensitive element.
- (6) The marking required for the inflation handle of a manual inflation mechanism must be waterproof, permanent, and readable from a distance of 2.5 m (8 feet).