46 C.F.R. § 160.066-12
(a) The procedure for conducting operational tests is described in figure (1).
(b) Each signal selected for the operational tests must be conditioned by:
(c) After each signal selected has undergone the conditioning required by paragraph (b) of this section it must be fired as described by the manufacturer's operating instructions. The following data as observed must be recorded for each signal:
(d) A signal fails the operational tests if:
(e) A lot is rejected if a “reject lot” decision is reached using Figure (1) and Table 1 after completion of the operational tests.

| Lot size | Individual sample size | Sample | Cumulative sample size | Accept 1 | Reject 1 |
|---|---|---|---|---|---|
| 280 or | 8 | First | 8 | (2) | 4 |
| less. | Second | 16 | 1 | 5 | |
| Third | 24 | 2 | 6 | ||
| Fourth | 32 | 3 | 7 | ||
| Fifth | 40 | 5 | 8 | ||
| Sixth | 48 | 7 | 9 | ||
| Seventh | 56 | 9 | 10 | ||
| 281 to | 13 | First | 13 | (2) | 4 |
| 500. | Second | 26 | 1 | 6 | |
| Third | 39 | 3 | 8 | ||
| Fourth | 52 | 5 | 10 | ||
| Fifth | 65 | 7 | 11 | ||
| Sixth | 78 | 10 | 12 | ||
| Seventh | 91 | 13 | 14 | ||
| 501 to | 20 | First | 20 | (2) | 5 |
| 1,200. | Second | 40 | 3 | 8 | |
| Third | 60 | 6 | 10 | ||
| Fourth | 80 | 8 | 13 | ||
| Fifth | 100 | 11 | 15 | ||
| Sixth | 120 | 14 | 17 | ||
| Seventh | 140 | 18 | 19 | ||
| 1,201 to | 32 | First | 32 | 1 | 7 |
| 3,200. | Second | 64 | 4 | 10 | |
| Third | 96 | 8 | 13 | ||
| Fourth | 128 | 12 | 17 | ||
| Fifth | 160 | 17 | 20 | ||
| Sixth | 192 | 21 | 23 | ||
| Seventh | 224 | 25 | 26 | ||
| More | 50 | First | 50 | 2 | 9 |
| than | Second | 100 | 7 | 14 | |
| 3,200. | Third | 150 | 13 | 19 | |
| Fourth | 200 | 19 | 25 | ||
| Fifth | 250 | 25 | 29 | ||
| Sixth | 300 | 31 | 33 | ||
| Seventh | 350 | 37 | 38 | ||
| 1 Cumulative number of failures. | |||||
| 2 Lot may not be accepted. Next sample must be tested. |