The tank design load calculations for a membrane tank must include the following:
- (a) Plastic deformation and fatigue life resulting from static and dynamic loads in the membrane and the supporting insulation.
- (b) The response of the membrane and its supporting insulation to vessel motion and acceleration under the worst weather conditions. Calculations from a similar vessel may be submitted to meet this paragraph.
- (c) The combined strains from static, dynamic, and thermal loads.