(a) Each cable and wire on a towing vessel must be installed to meet the following requirements:
- (1) Each conductor must have sufficient current-carrying capacity for the circuit in which it is used.
- (2) Cable hangers for overhead and vertical cable runs must be installed with metal supports and retention devices at least every 48 inches.
- (3) Each wire and cable run must be installed in a manner to prevent contact with personnel, mechanical hazards, and leaking fluids. Wire and cable runs must not be installed in bilges, across a normal walking path, or less than 24 inches from the path of movable machinery (e.g., cranes, elevators, forktrucks, etc., where the machinery location can change) unless adequately protected.
- (4) Connections and terminations must be suitable for the installed conductors, and must retain the original electrical, mechanical, flame-retarding, and where necessary, fire-resisting properties of the conductor. If twist-on types of connectors are used, the connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Twist-on type of connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit.
- (5) Each cable and wire must be installed so as to avoid or reduce interference with radio reception and compass indication.
- (6) Each cable and wire must be protected from the weather.
- (7) Each cable and wire must be supported in order to avoid chafing or other damage.
- (8) Each cable and wire must be protected by metal coverings or other suitable means, if in areas subject to mechanical abuse.
- (9) Each cable and wire must be suitable for low temperature and high humidity, if installed in refrigerated compartments.
- (10) Each cable and wire must be located outside a tank, unless it supplies power to equipment in the tank.
- (11) If wire is installed in a tank, it must have sheathing or wire insulation compatible with the fluid in a tank.
- (b) Extension cords must not be used as a permanent connection to a source of electrical power.
- (c) Multi-outlet adapters (power strips) may not be connected to other adapters (“daisy-chained”), or otherwise used in a manner that could overload the capacity of a receptacle.