(a) An inflatable liferaft or inflatable buoyant apparatus must be serviced at a facility specifically approved by the Commandant for the particular brand, and in accordance with servicing procedures meeting the requirements of part 160, subpart 160.151, of this chapter—
- (1) No later than the month and year on its servicing sticker affixed under 46 CFR 160.151-57(n), except that servicing may be delayed until the next scheduled inspection of the vessel, provided that the delay does not exceed 5 months; and
- (2) Whenever the container is damaged or the container straps or seals are broken.
(b) Each inflatable lifejacket and hybrid inflatable lifejacket or work vest must be serviced:
- (1) Within 12 months of its initial packing; and
- (2) Within 12 months of each subsequent servicing, except that servicing may be delayed until the next scheduled inspection of the OSV, provided that the delay does not exceed 5 months.
- (c) Each inflatable lifejacket must be serviced in compliance with subpart 160.176 of this chapter.
- (d) Each hybrid inflatable lifejacket or work vest must be serviced in accordance with the manual provided under § 160.077-29 of this chapter.
- (e) Repair and maintenance of inflatable rescue boats must follow the manufacturers' instructions. Each repair, except an emergency repair made aboard the vessel, must be made at a servicing facility approved by the Commandant (CG-ENG).
[CGD 82-004 and CGD 86-074, 62 FR 49340, Sept. 19, 1997, as amended by USCG-2002-11118, 67 FR 58541, Sept. 17, 2002; USCG-2009-0702, 74 FR 49235, Sept. 25, 2009; USCG-2012-0832, 77 FR 59782, Oct. 1, 2012]