- (a) Pipe may be fabricated by brazing when the temperature to which such connections may be subjected does not exceed 425 °F. (For exception refer to § 56.30-30(b)(1).)
- (b) The surfaces to be brazed must be clean and free from grease, oxides, paint, scale, and dirt of any kind.
- (c) After the parts to be joined have been thoroughly cleaned the edges to be brazed must be given an even coating of flux prior to heating the joint as a protection against oxidation.
[CGFR 68-82, 33 FR 18843, Dec. 18, 1968, as amended by USCG-2003-16630, 73 FR 65184, Oct. 31, 2008]