(b) Each item of lifesaving equipment, including unapproved equipment, must be maintained and inspected in accordance with:
(d) An escape route from a space where an individual may be employed or an accommodation space must not be obstructed.
| Item | Interval | Regulation | |
|---|---|---|---|
| Monthly | Annually | ||
| (1) Inflatable wearable personal flotation device (Type V commercial hybrid) | Servicing | 28.140 | |
| (2) Personal flotation devices, exposure suits and immersion suits | Inspect, clean and repair as necessary | 28.140 | |
| (3) Buoyant apparatus and life floats | Inspect, clean and repair as necessary | 28.140 | |
| (4) Inflatable liferaft | Servicing 1 | 28.140 | |
| (5) Inflatable buoyant apparatus | Servicing 1 | 28.140 | |
| (6) Hydrostatic release | Servicing 1 | 28.140 | |
| (7) Disposable hydrostatic release | Replace on or before expiration date | 28.140 | |
| (8) Undated batteries | Replace | 28.140 | |
| (9) Dated batteries 2 and other items | Replace on or before expiration date | 25.26-50, 28.140 | |
| (10) EPIRB | Test | 25.26-50 | |
| 1 For a new liferaft or inflatable buoyant apparatus, the first annual servicing may be deferred to two years from the date of first packing if so indicated on the servicing sticker. | |||
| 2 Water activated batteries must be replaced whenever they are used. |