43 C.F.R. § 3175.94
(a) The volume for each chart integrated must be determined as follows:
V = IMV × IV
Where: V = reported volume, Mcf IMV = integral multiplier value, as calculated under this section IV = the integral value determined by the integration process (also known as the “extension,” “integrated extension,” and “integrator count”)
(1) If the primary device is a flange-tapped orifice plate, a single IMV must be calculated for each chart or chart interval using the following equation:

Where: Cd = discharge coefficient or flow coefficient, calculated under API 14.3.3 or AGA Report No. 3 (1985), Section 5 (incorporated by reference, see § 3175.30) β = Beta ratio Y = gas expansion factor, calculated under API 14.3.3, Subsection 5.6 or AGA Report No. 3 (1985), Section 5 (incorporated by reference, see § 3175.30) d = orifice diameter, in inches Zb = supercompressibility at base pressure and temperature Gr = relative density (specific gravity) Zf = supercompressibility at flowing pressure and temperature Tf = average flowing temperature, in degrees Rankine