Your in situ burning plan must be consistent with any guidelines authorized by the National Contingency Plan and the appropriate Area Contingency Plan(s). Your in situ burning plan must include:
- (a) A description of the in situ burn equipment including its availability, location, and owner;
- (b) A discussion of your in situ burning procedures, including provisions for ignition of an oil spill;
- (c) A discussion of environmental effects of an in situ burn;
- (d) Your guidelines for well control and safety of personnel and property;
- (e) A discussion of the circumstances in which in situ burning may be appropriate;
- (f) Your guidelines for making the decision to ignite; and
- (g) An outline of the procedures you must follow to obtain approval for an in situ burn.