30 C.F.R. § 250.908
Link to an amendment published at 91 FR 35359, June 10, 2026.
(a) API RP 2A-WSD, Recommended Practice for Planning, Designing and Constructing Fixed Offshore Platforms (as incorporated by reference in § 250.198), requires that the design fatigue life of each joint and member be twice the intended service life of the structure. When designing your platform, the following table provides minimum fatigue life safety factors for critical structural members and joints.
| If . . . | Then . . . |
|---|---|
| (1) There is sufficient structural redundancy to prevent catastrophic failure of the platform or structure under consideration, | The results of the fatigue analysis must indicate a minimum calculated life of twice the design life of the platform. |
| (2) There is not sufficient structural redundancy to prevent catastrophic failure of the platform or structure, | The results of a fatigue analysis must indicate a minimum calculated life or three times the design life of the platform. |
| (3) The desirable degree of redundancy is significantly reduced as a result of fatigue damage, | The results of a fatigue analysis must indicate a minimum calculated life of three times the design life of the platform. |
[76 FR 64462, Oct. 18, 2011, as amended at 81 FR 36150, June 6, 2016]