(c) Magazines other than box type shall be:
- (1) Located in accordance with the current American Table of Distances for storage of explosives.
- (2) Detached structures located away from powerlines, fuel storage areas, and other possible sources of fire.
- (3) Constructed substantially of noncombustible material or covered with fire-resistant material.
- (4) Reasonably bullet resistant.
- (5) Electrically bonded and grounded if constructed of metal.
- (6) Made of nonsparking materials on the inside, including floors.
- (7) Provided with adequate and effectively screened ventilation openings near the floor and ceiling.
- (8) Kept locked securely when unattended.
- (9) Posted with suitable danger signs so located that a bullet passing through the face of a sign will not strike the magazine.
- (10) Used exclusively for storage of explosives or detonators and kept free of all extraneous materials.
- (11) Kept clean and dry in the interior, and in good repair.
- (12) Unheated, unless heated in a manner that does not create a fire or explosion hazard.