30 C.F.R. § 75.831
(a) Trailing cable and continuous mining machine electrical work procedures. Prior to performing electrical work, other than troubleshooting and testing, on the high-voltage trailing cable or the continuous mining machine, a qualified person must de-energize the power center and follow procedures specified in paragraph (1) or (2):
(1) If a trailing cable disconnecting switch is provided:
(2) If a trailing cable disconnecting switch is not provided and a cable coupler is used as a disconnecting device:
(b) Troubleshooting and testing the trailing cable. During troubleshooting and testing, the de-energized high-voltage cable may be disconnected from the power center only for that period of time necessary to locate the defective condition. Prior to troubleshooting and testing trailing cables, a qualified person must perform the following:
(1) If a trailing cable disconnecting switch is provided:
(2) If a trailing cable disconnecting switch is not provided and a cable coupler is used as a disconnecting device:
(c) Troubleshooting and testing limitations. Troubleshooting and testing energized circuits must be performed only:
(4) When using protective gloves in accordance with the following table:
| Circuit voltage | Type of glove required |
|---|---|
| Greater than 120 volts (nominal) (not intrinsically safe) | Rubber insulating gloves with leather protectors. |
| 40 volts to 120 volts (nominal) (both intrinsically safe and non-intrinsically safe) | Either rubber insulating gloves with leather protectors or dry work gloves. |
| Greater than 120 volts (nominal) (intrinsically safe) | Either rubber insulating gloves with leather protectors or dry work gloves. |
(d) Power center electrical work procedures. Before any work is performed inside any compartment of the power center, except for troubleshooting and testing energized circuits as specified in paragraph (c) of this section, a qualified person must:
(e) Locking out and tagging responsibilities.
(2) If the person who installed the lock and tag is unavailable, the lock and tag may be removed by a person authorized by the operator, provided that: