(a) Guarding.
(1) The high-voltage cable must be guarded in the following locations:
- (i) From the power center cable coupler for a distance of 10 feet inby the power center;
- (ii) From the entrance gland for a distance of 10 feet outby the last strain clamp on the continuous mining machine; and,
- (iii) At any location where the cable could be damaged by moving equipment.
- (2) Guarding must be constructed using nonconductive flame-resistant material or grounded metal.
(b) Suspended cables and cable crossovers. When equipment must cross any portion of the cable, the cable must be either:
- (1) Suspended from the mine roof; or
(2) Protected by a cable crossover having the following specifications:
- (i) A minimum length of 33 inches;
- (ii) A minimum width of 17 inches;
- (iii) A minimum height of 3 inches;
- (iv) A minimum cable placement area of two and one half-inches (2 1/2″) high by four and one-quarter inches (4 1/4″) wide;
- (v) Made of nonconductive material;
- (vi) Made of material with a distinctive color. The color black must not be used; and
- (vii) Made of material that has a minimum compressive strength of 6,400 pounds per square inch (psi).
[75 FR 17549, Apr. 6, 2010]