As used in this part:
- (a) MSHA means the United States Department of Labor, Mine Safety and Health Administration.
- (b) Applicant means an individual, partnership, company, corporation, association, or other organization that designs, manufactures, or assembles and that seeks certification or preliminary testing of a methane-monitoring system or component.
- (c) Methane-monitoring system means a complete assembly of one or more methane detectors and all other components required for measuring and signalling the presence of methane in the atmosphere of a mine, tunnel, or other underground workings, and shall include a power-shutoff component.
- (d) Methane detector means a component for a methane-monitoring system that functions in a gassy mine, tunnel, or other underground workings to sample the atmosphere continuously and responds to the presence of methane.
- (e) Power-shutoff component means a component of a methane-monitoring system, such as a relay, switch, or switching mechanism, that will cause a control circuit to deenergize a machine, equipment, or power circuit when actuated by the methane detector.
- (f) Flammable mixture means a mixture of a gas, such as methane, natural gas, or similar hydrocarbon gas with normal air, that can be ignited.
- (g) Gassy mine or tunnel means a mine, tunnel, or other underground workings in which a flammable mixture has been ignited, or has been found with a permissible flame safety lamp, or has been determined by air analysis to contain 0.25 percent or more (by volume) of methane in any open workings when tested at a point not less than 12 inches from the roof, face, or rib.
(h) Letter of certification means a formal document issued by MSHA stating that a methane-monitoring system or subassembly or component thereof:
- (1) Has met the requirements of this part, and
- (2) Is certified for incorporation in or with permissible or approved equipment that is used in gassy mines and tunnels.
- (i) Component means a part of a methane-monitoring system that is essential to its operation as a certified methane-monitoring system.
- (j) Explosion-proof means that a component or group of components (subassembly) is so constructed and protected by an enclosure with or without a flame arrester(s) that, if a flammable mixture of gas is ignited within the enclosure, it will withstand the resultant pressure without damage to the enclosure and/or flame arrester(s). Also the enclosure and/or flame arrester(s) shall prevent the discharge of flame from within either the enclosure or the flame arrester, or the ignition of any flammable mixture that surrounds the enclosure and/or flame arrester. 1
- (k) Normal operation means that performance of each component as well as of the entire assembly of the methane-monitoring system is in conformance with the functions for which it was designed and for which it was tested by MSHA.
- (l) Flame arrester means a device so constructed that it will prevent propagation of flame or explosion from within the unit of which it is part to a surrounding flammable mixture.
- (m) Intrinsically safe equipment and circuitry means equipment and circuitry that are incapable of releasing enough electrical or thermal energy under normal or abnormal conditions to cause ignition of a flammable mixture of the most easily ignitable composition.
- (n) Fail safe means that the circuitry of a methane-monitoring system shall be so designed that electrical failure of a component which is critical in MSHA's opinion will result in deenergizing the methane-monitoring system and the machine or equipment of which it is a part.
1 Explosion-proof components or subassemblies shall be constructed in accordance with the requirements of Part 18 of this subchapter.
[31 FR 10607, Aug. 9, 1966, as amended at 39 FR 24003, June 28, 1974; 43 FR 12316, Mar. 24, 1978]