(a) General requirements.
- (1) Exposed moving parts such as gears, projecting screws, setscrews, chain, cables, chain sprockets, and reciprocating or rotating parts, which constitute a hazard, shall be guarded.
- (2) All controls used during the normal operation cycle shall be located within easy reach of the operator's station.
(3) Electric motor operated hoists shall be provided with:
- (i) A device to disconnect all motors from the line upon power failure and not permit any motor to be restarted until the controller handle is brought to the “off” position;
- (ii) Where applicable, an overspeed preventive device;
- (iii) A means whereby remotely operated hoists stop when any control is ineffective.
- (4) All base-mounted drum hoists in use shall meet the applicable requirements for design, construction, installation, testing, inspection, maintenance, and operations, as prescribed by the manufacturer.
- (b) Specific requirements. [Reserved]
- (c) This section does not apply to base-mounted drum hoists used in conjunction with derricks. Base-mounted drum hoists used in conjunction with derricks must conform to § 1926.1436(e).
[44 FR 8577, Feb. 9, 1979, as amended at 75 FR 48134, Aug. 9, 2010]