(a) Processing the plasma.
- (1) The plasma shall be separated from the red blood cells by centrifugation to obtain essentially cell-free plasma.
- (2) The plasma shall be placed in a freezer within 8 hours after blood collection or within the timeframe specified in the directions for use for the blood collecting, processing, and storage system. A combination of dry ice and organic solvent may be used for freezing: Provided, That the procedure has been shown not to cause the solvent to penetrate the container or leach plasticizer from the container into the plasma.
- (3) Immediately after separation and freezing of the plasma, the plasma shall be stored and maintained at −18 °C or colder until thawing of the plasma for further processing to remove the Cryoprecipitated AHF.
(b) Processing the final product.
- (1) The Cryoprecipitated AHF shall be separated from the plasma by a procedure that has been shown to produce an average of no less than 80 units of antihemophilic factor per final container.
- (2) No diluent shall be added to the product by the manufacturer prior to freezing.
- (3) The final container used for Cryoprecipitated AHF shall be colorless and transparent to permit visual inspection of the contents; any closure shall maintain a hermetic seal and prevent contamination of the contents. The container material shall not interact with the contents under customary conditions of storage and use in such a manner as to have an adverse effect upon the safety, purity, potency and effectiveness of the product. At the time of filling, the final container shall be identified by a number so as to relate it to the donor.
[42 FR 21774, Apr. 29, 1977, as amended at 47 FR 15330, Apr. 9, 1982; 50 FR 4139, Jan. 29, 1985; 64 FR 45373, Aug. 19, 1999; 66 FR 1837, Jan. 10, 2001; 66 FR 40890, Aug. 6, 2001]