16 C.F.R. § 1611.4
(a) Apparatus and materials. The apparatus shall be constructed essentially as shown in figure 1 and shall consist of the following:
(1) Specimen holder.
(b) Test specimens.
(c) Procedure.
(5) The burning time shall be read from the stop clock and the rate of burning calculated. Results that deviate from the mean value of all tests should be rejected if the deviation of the doubtful value is more than five times the average deviation from the mean obtained by excluding the doubtful value. Such doubtful values shall be discarded and retests made.