(b) Contents of specification. The product specification shall include the following information:
- (1) A description of the equipment used to manufacture the insulation, including the model number and names of the equipment manufacturers, and details of any modification made to any item of equipment.
- (2) A description of the cellulosic stock material used to manufacture the insulation, identifying the extent of impurities allowed.
- (3) The formulation of the fire-retardant chemicals added, including their chemical constituents and their form (for example, granulated, powdered, or liquid); the amount of fire-retardant chemicals present in the finished insulation, expressed as a percentage of the total weight of chemicals and cellulosic stock; the average weight of chemicals per bag; and the name and address of each chemical supplier. Where the chemical composition or formula of a commercially pre-mixed fire retardant is not known to the insulation manufacturer, the pre-mixed fire retardant may be described simply by the name and address of the supplier and its brand or trade name.
- (4) A description of the tests which were used to qualify the product as well as the dates of performance and results and actual values, where applicable, of the tests.
- (5) Any other information necessary to describe the insulation.