14 C.F.R. § 171.259
(a) The ISMLS consists of the following basic components:
(c) ISMLS ground equipment must meet the following service conditions:
(1) AC line parameters, DC voltage, elevation, and duty:
120 V nominal value, 102 V to 138 V (±1 V).* 208 V nominal value, 177 V to 239 V (±2 V).* 240 V nominal value, 204 V to 276 V (±0.2 V).* AC line frequency (60 Hz), 57 Hz to 63 Hz (±0.2 Hz).* DC voltage (48 V), 44 V to 52 V (±0.5 V).* * Note: Where discrete values of the above frequency or voltages are specified for testing purposes, the tolerances given in parentheses indicated by an asterisk apply to the test instruments used to measure these parameters. Elevation, 0 to 10,000 ft. above sea level. Duty, continuous, unattended.
(2) Ambient conditions for localizer and glide path equipment:
Temperature, −10 °C to + 50 °C. Relative humidity, 5% to 90%.
(3) Ambient conditions for marker beacon facilities and all other equipment installed outdoors (for example, antennae, field detectors, and shelters):
Temperature, −50 °C. to + 70 °C. Relative humidity, 5% to 100%.
(4) All equipment installed outdoors must operate satisfactorily under the following conditions:
Wind velocity, 0-100 MPH (not including gusts). Hail stones, 1/2″ diameter. Rain, provide coverage through a distance of 5 nautical miles with rain falling at a rate of 50 millimeters per hour, and with rain falling at the rate of 25 millimeters per hour for the additional design performance range of the system. Ice loading, encased in 1/2″ radial thickness of clear ice.
(d) The ISMLS must perform in accordance with the following standards and practices for Facility Performance Category I operation:
(e) The signal format and pairing of the runway localizer and glide path transmitter frequencies of an ISMLS must be in accordance with the frequency plan approved by the FAA, and must meet the following signal format requirements: