14 C.F.R. § 27.1357
(a) Protective devices, such as fuses or circuit breakers, must be installed in each electrical circuit other than—
(c) Each resettable circuit protective device (“trip free” device in which the tripping mechanism cannot be overridden by the operating control) must be designed so that—
(e) If fuses are used, there must be one spare of each rating, or 50 percent spare fuses of each rating, whichever is greater.