14 C.F.R. Appendix D to Part 27
This appendix specifies the HIRF environments and equipment HIRF test levels for electrical and electronic systems under § 27.1317. The field strength values for the HIRF environments and laboratory equipment HIRF test levels are expressed in root-mean-square units measured during the peak of the modulation cycle.
(a) HIRF environment I is specified in the following table:
| Frequency | Field strength(volts/meter) | |
|---|---|---|
| Peak | Average | |
| 10 kHz-2 MHz | 50 | 50 |
| 2 MHz-30 MHz | 100 | 100 |
| 30 MHz-100 MHz | 50 | 50 |
| 100 MHz-400 MHz | 100 | 100 |
| 400 MHz-700 MHz | 700 | 50 |
| 700 MHz-1 GHz | 700 | 100 |
| 1 GHz-2 GHz | 2,000 | 200 |
| 2 GHz-6 GHz | 3,000 | 200 |
| 6 GHz-8 GHz | 1,000 | 200 |
| 8 GHz-12 GHz | 3,000 | 300 |
| 12 GHz-18 GHz | 2,000 | 200 |
| 18 GHz-40 GHz | 600 | 200 |
| In this table, the higher field strength applies at the frequency band edges. |
(b) HIRF environment II is specified in the following table:
| Frequency | Field strength(volts/meter) | |
|---|---|---|
| Peak | Average | |
| 10 kHz-500 kHz | 20 | 20 |
| 500 kHz-2 MHz | 30 | 30 |
| 2 MHz-30 MHz | 100 | 100 |
| 30 MHz-100 MHz | 10 | 10 |
| 100 MHz-200 MHz | 30 | 10 |
| 200 MHz-400 MHz | 10 | 10 |
| 400 MHz-1 GHz | 700 | 40 |
| 1 GHz-2 GHz | 1,300 | 160 |
| 2 GHz-4 GHz | 3,000 | 120 |
| 4 GHz-6 GHz | 3,000 | 160 |
| 6 GHz-8 GHz | 400 | 170 |
| 8 GHz-12 GHz | 1,230 | 230 |
| 12 GHz-18 GHz | 730 | 190 |
| 18 GHz-40 GHz | 600 | 150 |
| In this table, the higher field strength applies at the frequency band edges. |
(c) HIRF environment III is specified in the following table:
| Frequency | Field strength(volts/meter) | |
|---|---|---|
| Peak | Average | |
| 10 kHz-100 kHz | 150 | 150 |
| 100 kHz-400 MHz | 200 | 200 |
| 400 MHz-700 MHz | 730 | 200 |
| 700 MHz-1 GHz | 1,400 | 240 |
| 1 GHz-2 GHz | 5,000 | 250 |
| 2 GHz-4 GHz | 6,000 | 490 |
| 4 GHz-6 GHz | 7,200 | 400 |
| 6 GHz-8 GHz | 1,100 | 170 |
| 8 GHz-12 GHz | 5,000 | 330 |
| 12 GHz-18 GHz | 2,000 | 330 |
| 18 GHz-40 GHz | 1,000 | 420 |
| In this table, the higher field strength applies at the frequency band edges. |
(d) Equipment HIRF Test Level 1.
(f) Equipment HIRF Test Level 3.
[Doc. No. FAA-2006-23657, 72 FR 44027, Aug. 6, 2007]