This appendix specifies the HIRF environments and equipment HIRF test levels for electrical and electronic systems under § 25.1317. The field strength values for the HIRF environments and equipment HIRF test levels are expressed in root-mean-square units measured during the peak of the modulation cycle.
(a) HIRF environment I is specified in the following table:
Table I.—HIRF Environment I| Frequency | Field strength(volts/meter) |
|---|
| Peak | Average |
|---|
| 10 kHz-2 MHz | 50 | 50 |
| 2 MHz-30 MHz | 100 | 100 |
| 30 MHz-100 MHz | 50 | 50 |
| 100 MHz-400 MHz | 100 | 100 |
| 400 MHz-700 MHz | 700 | 50 |
| 700 MHz-1 GHz | 700 | 100 |
| 1 GHz-2 GHz | 2,000 | 200 |
| 2 GHz-6 GHz | 3,000 | 200 |
| 6 GHz-8 GHz | 1,000 | 200 |
| 8 GHz-12 GHz | 3,000 | 300 |
| 12 GHz-18 GHz | 2,000 | 200 |
| 18 GHz-40 GHz | 600 | 200 |
| In this table, the higher field strength applies at the frequency band edges. |
(b) HIRF environment II is specified in the following table:
Table II.-HIRF Environment II| Frequency | Field strength(volts/meter) |
|---|
| Peak | Average |
|---|
| 10 kHz-500 kHz | 20 | 20 |
| 500 kHz-2 MHz | 30 | 30 |
| 2 MHz-30 MHz | 100 | 100 |
| 30 MHz-100 MHz | 10 | 10 |
| 100 MHz-200 MHz | 30 | 10 |
| 200 MHz-400 MHz | 10 | 10 |
| 400 MHz-1 GHz | 700 | 40 |
| 1 GHz-2 GHz | 1,300 | 160 |
| 2 GHz-4 GHz | 3,000 | 120 |
| 4 GHz-6 GHz | 3,000 | 160 |
| 6 GHz-8 GHz | 400 | 170 |
| 8 GHz-12 GHz | 1,230 | 230 |
| 12 GHz-18 GHz | 730 | 190 |
| 18 GHz-40 GHz | 600 | 150 |
| In this table, the higher field strength applies at the frequency band edges. |
(c) Equipment HIRF Test Level 1.
- (1) From 10 kilohertz (kHz) to 400 megahertz (MHz), use conducted susceptibility tests with continuous wave (CW) and 1 kHz square wave modulation with 90 percent depth or greater. The conducted susceptibility current must start at a minimum of 0.6 milliamperes (mA) at 10 kHz, increasing 20 decibels (dB) per frequency decade to a minimum of 30 mA at 500 kHz.
- (2) From 500 kHz to 40 MHz, the conducted susceptibility current must be at least 30 mA.
- (3) From 40 MHz to 400 MHz, use conducted susceptibility tests, starting at a minimum of 30 mA at 40 MHz, decreasing 20 dB per frequency decade to a minimum of 3 mA at 400 MHz.
- (4) From 100 MHz to 400 MHz, use radiated susceptibility tests at a minimum of 20 volts per meter (V/m) peak with CW and 1 kHz square wave modulation with 90 percent depth or greater.
- (5) From 400 MHz to 8 gigahertz (GHz), use radiated susceptibility tests at a minimum of 150 V/m peak with pulse modulation of 4 percent duty cycle with a 1 kHz pulse repetition frequency. This signal must be switched on and off at a rate of 1 Hz with a duty cycle of 50 percent.
- (d) Equipment HIRF Test Level 2. Equipment HIRF test level 2 is HIRF environment II in table II of this appendix reduced by acceptable aircraft transfer function and attenuation curves. Testing must cover the frequency band of 10 kHz to 8 GHz.
(e) Equipment HIRF Test Level 3.
- (1) From 10 kHz to 400 MHz, use conducted susceptibility tests, starting at a minimum of 0.15 mA at 10 kHz, increasing 20 dB per frequency decade to a minimum of 7.5 mA at 500 kHz.
- (2) From 500 kHz to 40 MHz, use conducted susceptibility tests at a minimum of 7.5 mA.
- (3) From 40 MHz to 400 MHz, use conducted susceptibility tests, starting at a minimum of 7.5 mA at 40 MHz, decreasing 20 dB per frequency decade to a minimum of 0.75 mA at 400 MHz.
- (4) From 100 MHz to 8 GHz, use radiated susceptibility tests at a minimum of 5 V/m.
[Doc. No. FAA-2006-23657, 72 FR 44026, Aug. 6, 2007]