10 C.F.R. § 431.326
(a) Except as provided in paragraph (b) of this section, each metal halide lamp fixture manufactured on or after January 1, 2009, and designed to be operated with lamps rated greater than or equal to 150 watts but less than or equal to 500 watts shall contain—
(b) The standards described in paragraph (a) of this section do not apply to—
(3) Metal halide lamp fixtures that;
(c) Except when the requirements of paragraph (a) of this section are more stringent (i.e., require a larger minimum efficiency value) or as provided by paragraph (e) of this section, each metal halide lamp fixture manufactured on or after February 10, 2017, must contain a metal halide ballast with an efficiency not less than the value determined from the appropriate equation in the following table:
| Designed to beoperated with lamps of the following rated lamp wattage | Tested inputvoltage‡‡ | Minimum standard equation‡‡% |
|---|---|---|
| ≥50 W and ≤100 W | Tested at 480 V | (1/(1 + 1.24 × P^(−0.351))) − 0.020†† |
| ≥50 W and ≤100 W | All others | 1/(1 + 1.24 × P^(−0.351)) |
| >100 W and <150† W | Tested at 480 V | (1/(1 + 1.24 × P^(−0.351))) − 0.020 |
| >100 W and <150† W | All others | 1/(1 + 1.24 × P^(−0.351)) |
| ≥150 ‡ W and ≤250 W | Tested at 480 V | 0.880 |
| ≥150 ‡ W and ≤250 W | All others | For ≥150 W and ≤200 W: 0.880 |
| For >200 W and ≤250 W: 1/(1 + 0.876 × P^(−0.351)) | ||
| >250 W and ≤500 W | Tested at 480 V | For >250 and <265 W: 0.880 |
| For ≥265 W and ≤500 W: (1/(1 + 0.876 × P^(−0.351)) − 0.010 | ||
| >250 W and ≤500 W | All others | 1/(1 + 0.876 × P^(−0.351)) |
| >500 W and ≤1000 W | Tested at 480 V | For >500 W and ≤750 W: 0.900 |
| For >750 W and ≤1000 W: 0.000104 × P + 0.822 | ||
| For >500 W and ≤1000 W: may not utilize a probe-start ballast | ||
| >500 W and ≤1000 W | All others | For >500 W and ≤750 W: 0.910 |
| For >750 W and ≤1000 W: 0.000104 × P + 0.832 | ||
| For >500 W and ≤1000 W: may not utilize a probe-start ballast | ||
| † Includes 150 W fixtures specified in paragraph (b)(3) of this section, that are fixtures rated only for 150 W lamps; rated for use in wet locations, as specified by the NFPA 70 (incorporated by reference, see § 431.323), section 410.4(A); and containing a ballast that is rated to operate at ambient air temperatures above 50 °C, as specified by UL 1029 (incorporated by reference, see § 431.323). | ||
| ‡ Excludes 150 W fixtures specified in paragraph (b)(3) of this section, that are fixtures rated only for 150 W lamps; rated for use in wet locations, as specified by the NFPA 70, section 410.4(A); and containing a ballast that is rated to operate at ambient air temperatures above 50 °C, as specified by UL 1029. | ||
| †† P is defined as the rated wattage of the lamp the fixture is designed to operate. | ||
| ‡‡ Tested input voltage is specified in 10 CFR 431.324. |
(e) The standards described in paragraphs (c) and (d) of this section do not apply to—
[74 FR 12075, Mar. 23, 2009, as amended at 79 FR 7844, Feb. 10, 2014]