- (a) Recessed floor conveyor systems shall be designed and installed to minimize tripping hazards. Where a tripping hazard(s) exists, the hazard(s) shall be identified by painting it a distinctive color or otherwise be conspicuously marked.
(b) Rails for roll stands and other rail mounted devices shall be installed to comply with the following:
- (1) The rails shall be flush with the floor; and
- (2) A minimum 18-inch clearance shall be provided between the device(s) and fixed equipment or walls.
- (c) Corrugating and pressure rolls shall be equipped with threading guides designed and installed to prevent contact with the operating feed nip.
- (d) A minimum 4-inch clearance shall be maintained between heated drums, idler rolls and cross shafting on all preheaters and preconditioners.
- (e) A minimum 4-inch nip clearance shall be maintained on the lower elevating conveyor belt rolls of single facer bridges.
- (f) Slitter stations not in use shall be disconnected from the power source by positive means.
- (g) The adhesive exhaust system shall be designed, installed and maintained to comply with the permissive exposure limits (PEL) contained in Article 107.
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.