(b) The nozzle of air, high pressure water cleaning systems, grit cleaning systems, inert gas and steam lines or hoses, when used in the cleaning or ventilation of tanks and vessels that may contain hazardous concentrations of flammable gases or vapors, shall be grounded and bonded to the tank or vessel shell. Bonding devices shall not be attached nor detached in hazardous concentrations of flammable gases or vapors. Before starting work, precautions shall be taken to prevent ignition of flammable atmospheres in tanks and vessels in accordance with the requirements of Section 5420 of these Orders.
Exception: High pressure water cleaning system nozzles used to clean tanks or vessels 100 cubic meters or less in size need not be bonded to the tank or vessel shell, provided all conductive components are grounded and it is not possible for steam to enter the tank or vessel.
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
1. Amendment filed 12-10-87; operative 1-9-88 (Register 87, No. 51).
2. Amendment of subsection (b) and new subsection (e) filed 8-26-2008; operative 9-25-2008 (Register 2008, No. 35).