Cal. Code Regs. tit. 8, § 5023
(b) Proof load tests and safe working load ratings shall be based on the designed load ratings at the ranges of boom angle or operating radii. Proof loads shall exceed the safe working load (SWL) as follows:
SWL
Proof Load
Up to 20 tons
25 percent in excess
20-50 tons
5 tons in excess
Over 50 tons
10 percent in excess
Proof loads shall be applied at the designed maximum and minimum boom angles or radii or, if this is impracticable, as close to these as practicable. The angles or radii of test shall be in the certificate of test. Proof loads shall be swung as far as possible in both directions. The weight of all auxiliary handling devices such as blocks, hooks, etc., shall be considered a part of the load.
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
1. Amendment filed 8-29-86; effective thirtieth day thereafter (Register 86, No. 39).