Cal. Code Regs. tit. 8, § 3120.11
(b) Hoistway access switches shall comply with section 3021(k)(1), excluding the exception, and section 3021(k)(2)(B).
(Title 24, Part 7, Section 7-3120.11.)
Hoistway-door locking devices, car door or gate electric contacts, hoistway access switches and elevator parking devices shall comply with Section 111 of ASME A17.1-1996; except for Rules 111.9a, 111.9d, 111.9e and 111.10; which is hereby incorporated by reference.
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code; and Section 18943(b), Health and Safety Code.
1. New section filed 9-25-98; operative 10-25-98 (Register 98, No. 39).