Cal. Code Regs. tit. 8, § 3071
(a) Types of Operating Devices.
(2) Top-of-car operating devices shall be provided and shall conform to the requirements of section 3040(a)(4).
Exceptions:
(c) Leveling Devices and Truck-Zoning Devices.
(d) Electrical Protective Devices. In addition to the terminal stopping devices required by section 3070, the following electrical protective devices shall be provided and shall conform to the requirements of section 3040(b), except that their operation shall cause the electrical power to be removed from all control valves and from the pump motor.
(6) Electric contacts for hinged car-platform sills.
Exception: Devices (4), (5), and (6) need not remove the power within the leveling zones.
(g) Control and Operating Circuit Requirements. The design and installation of the control and operating circuits shall conform to the following requirements:
(2) The completion or maintenance of an electric circuit shall not be used to interrupt the power to control-valve-operating magnets nor to the pump-driving motor under the following conditions:
(j) Load Test Required. Every hydraulic elevator installed hereafter shall be field tested before a permit to operate is issued, and again at intervals not to exceed five (5) years.
(1) The test shall be witnessed by an authorized representative of the Division, or the Division may accept reports of witnesses accepted by the Division as competent. This test shall demonstrate that:
(A) When running the car with rated load in both directions:
1. The rated speed as shown on the crosshead data plate shall not be greater than 110 percent of the actual speed in the up direction with the rated load on the car.
Exception to Section 3071(j)(1)(A)1:
For elevators installed prior to 3-21-70 the Division may accept a greater percentage of the actual speed.
(2) A metal, fiber, or plastic tag shall be securely attached to the elevator pumping unit in the machine room, with lettering not less than ¼ in. (6.4 mm) on a contrasting background indicating the following information:
(k) Out-of-Service Requirements.
(2) The car shall be landed in a satisfactory manner.
Note: To facilitate reactivation of the elevator, the car should be landed at least 2 feet above the bottom terminal.
(l) Operation of Elevators Under Fire or Other Emergency Conditions.
(1) Elevators with automatic operation shall conform to fire and other emergency requirements as follows:
(o) Medical Emergency Elevators. All buildings and structures constructed after the effective date of this order that are provided with one or more passenger elevators shall conform to the requirements of section 3041(e).
(Title 24, Part 7, Section 7-3071)
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
1. New subsection (l) filed 9-5-75; effective thirtieth day thereafter (Register 75, No. 36).
2. New subsection (m) filed 11-24-76; effective thirtieth day thereafter (Register 76, No. 48).
3. Amendment of subsections (a), (b) and (k) filed 6-23-77; effective thirtieth day thereafter (Register 77, No. 26).
4. Amendment of subsection (c); repealer and new subsection (l) filed 12-22-78; effective thirtieth day thereafter (Register 79, No. 1).
5. Amendment filed 12-8-86; effective thirtieth day thereafter (Register 86, No. 50).
6. New subsections (n) and (o) approved by the Building Standards Commission on 5-24-91 and filed 6-12-91; operative 7-12-91 (Register 91, No. 34).
7. Amendment of subsections (e) and (o) and repealer of subsections (e)(1)-(2) filed 6-29-94; operative 7-29-94 (Register 94, No. 26).
8. Redesignation of subsections (j)(1)-(j)(1)(E), amendment of subsection (j)(1)(A)1 Exception, subsections (j)(1)(B), (D) and (E) and new subsections (j)(2)-(j)(2)3 filed 12-6-94; operative 1-5-95 (Register 94, No. 49).
9. Editorial correction of subsections (a)(2) Exception 2 and (j)(2) (Register 95, No. 32).
10. Amendment of subsections (j)(1)(A) and (j)(1)(C) and deletion of subsection (j)(1)(E) approved by the Building Standards Commission on 1-31-2001 and filed 2-2-2001; operative 3-4-2001. Submitted to OAL for printing only (Register 2001, No. 13).