Cal. Code Regs. tit. 8, § 3070
(a) Normal Terminal Stopping Devices.
Normal terminal stopping devices shall be provided, conforming to the requirements of Section 3039(a).
Exceptions:
(b) Emergency Terminal Stopping Devices. Emergency terminal stopping devices shall be installed at the top of the hoistway for rated car speeds of more than 100 feet per minute and shall conform to the following:
(4) A single short circuit caused by a combination of grounds or by other conditions shall not prevent the functioning of the emergency terminal stopping device.
Exception: Where the plunger is provided with a device to retard the car to 100 feet per minute, with a retardation not greater than gravity, before the plunger reaches its extreme limit of travel, emergency terminal stopping devices are not required.
(c) Final Terminal Stopping Devices. Final terminal stopping devices are not required.
(Title 24, Part 7, Section 7-3070)
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code; and Section 18943, Health and Safety Code.
1. New Note filed 12-8-86; effective thirtieth day thereafter (Register 86, No. 50).
2. New Exception 3. to subsection (a), statement prior to Note and amendment of Note filed 3-9-93; operative 4-8-93 (Register 93, No. 11).