Cal. Code Regs. tit. 8, § 3014
(a) Guarding in Machine Rooms and Machinery Spaces. The following equipment located in machine rooms or machinery spaces shall be guarded to protect against accidental contact:
(1) Exposed external moving parts such as gears, sprockets, sheaves, drums, shafts and their driving ropes, chains or tapes for selectors, floor controllers or signal machines.
Exception to subsection 3014(a)(1):
Guards are not required for equipment located more than 7 ft (2.13m) above the floor.
(3) All moving parts of the equipment in secondary sheave spaces shall be completely guarded except the governor sheave and flyballs. Expanded metal or grillwork shall be used for secondary sheave guards.
Exception: Guards are not required for equipment located more than 7 ft (2.13m) above the secondary sheave space floor.
(b) Guarding in the Hoistway and On the Car. The following equipment located in the elevator hoistway or on the elevator car shall be guarded to protect against accidental contact:
(c) Rope Retainer Guards. Rope retainer guards shall be provided on deflector sheaves, machine sheaves, compensator rope sheaves, governor tension sheaves and hoist rope sheaves on cars and counterweights to inhibit displacement of ropes in the event ropes become slack.
Rope guards shall be continuous or there shall be one restraint for 30 degrees wrap or less, and two restraints for wraps in excess of 30 degrees. Where one restraint is furnished, it shall divide the arc of contact into equal parts. Where two restraints are furnished, they shall be located approximately 1/6 of the arc of contact from the nip points.
(d) Snag Guards. Snag points created by rail brackets, clip bolts and fishplates shall be provided with guards to prevent snagging of the following:
(4) Traveling cables hung so any portion of their loop below the hatch junction box is within 36 in. (914mm) horizontally of a potential snag point.
(Title 24, Part 7, Section 7-3014.)
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
1. New subsections (c) and (d) filed 9-5-75; effective thirtieth day thereafter (Register 75, No. 36).
2. Section 3014(c) and (d) which was filed 9-5-75 (Register 75, No. 36), was approved by the Building Standards Commission 3-26-76. History note printed in Register 78, No. 30 for technical reasons.
3. Amendment of exceptions in subsections (c) and (d)(4) filed 12-22-78; effective thirtieth day thereafter (Register 79, No. 1).
4. Amendment filed 6-23-87; operative 6-23-87 (Register 87, No. 27).