Cal. Code Regs. tit. 8, § 3092
(a) Devices Required.
(4) Moving walks required by Section 3091(n)(2) to be equipped with a brake, or which are driven by a direct current motor, shall be provided with a speed governor which will cause the interruption of power to the driving machine and to the brake, where provided, should the speed of the treadway exceed a predetermined value, which shall be not more than 40 percent above the maximum designed treadway speed.
Exception:
Operating and safety devices shall be provided conforming to the following requirements:
2. Moving walks driven by low slip-alternating current induction motors connected to the driving machine by belts or chains, where a device is provided which will cause interruption of power to the motor and apply the brake should the belts lose driving tension or should the belts or chains break.
(7) Each space containing moving parts, where a means of access is provided, shall be equipped with a stop switch located adjacent to the access door or panel. The stop switches shall:
(c) Access and Work Space. Sufficient clearance shall be provided within the machine room for safe access as required for inspection and maintenance, and safe access shall be provided to the machine room.
Floor access panels, in excess of 70 pounds, shall be counterbalanced or provided with means to lift and move the panel away from the machinery space.
(d) Guarding in Machine Space. On pallet type moving walks, a guard shall be provided between the machine room and the pallets to prevent accidental contact with the moving pallets.
(Title 24, Part 7, Section 7-3092)
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
1. Amendment of subsection (a)(1) filed 6-23-77; effective thirtieth day thereafter (Register 77, No. 26).
2. Amendment of subsection (a)(7) filed 12-22-78; effective thirtieth day thereafter (Register 79, No. 1).
3. Amendment of subsections (b) and (d) and Note filed 6-29-94; operative 7-29-94 (Register 94, No. 26).